30 STAR TRAC PRO BIKES O
WNER
S
G
UIDE
Lowest Highest Default
Item Value Value Value Meaning
Time 5 99 20 Maximum time in minutes allowed for program, excluding warm-up and cool-
down.
Weight 50 (Lb) 350 (Lb) 155 lbs Default (to user), typical weight in lb (UNITS=English), or kg
22 (KG) 158 (KG) 70 (KG) (UNITS=Metric).
Language N/A N/A English Language in English, Dutch, French, German, Portuguese, Spanish, Swedish,
Italian or Katakana.
Model N/A N/A PB-UB PB-UB = Pro Bike - Upright
PB-RB = Pro Bike - Recumbent
NAT-RUNNER = Natural Runner
OPER Hours 0 65535 0 Total operating hours
BATT Hours 0 65535 0 Total battery use hours
Quick Start 0 65535 0 Number of times the Quick Start program was run since last reset.
Manual 0 65535 0 Number of times the Manual Program was run since last reset.
Warm Up 0 65535 0 Number of times the Warm Up Program was run since last reset.
Auto Pilot 0 65535 0 Number of times the Auto Pilot Program was run since last reset.
IHR Program 0 65535 0 Number of times the Interval Heart Rate Control Program was run since last
reset.
CHR Program 0 65535 0 Number of times the Constant Heart Rate Control Program was run since
last reset.
WI Program 0 65535 0 Number of times the Watts Interval Program was run since last reset.
CW Program 0 65535 0 Number of times the Continuous Watts Program was run since last reset.
Fit Test 0 65535 0 Number of times the Fitness Test Program was run since last reset.
Alpine 0 65535 0 Number of times the Alpine Pass Program was run since last reset.
Rndm Prog 0 65535 0 Number of times the Random Hill Program was run since last reset.
Over Temp 0 65535 0 Number of times an “Over Temperature” condition occurred since last reset.
No Temp 0 65535 0 Number of times a “No Temperature” condition occurred since last reset.
Low Batt 0 65535 0 Number of times a “Low Battery” condition occurred since last reset.
Comm Lost 0 65535 0 Number of times a “Communication Lost” condition occurred since last reset.
Key Down 0 65535 0 Number of times a “Key Down” condition occurred since last reset.
LED Test N/A N/A N/A Access to integral LED test function (for use by authorized Maintenance
Technician).
Keypad Test N/A N/A N/A Access to integral keypad test function (for use by authorized Maintenance
Technician).
Heart Rate N/A N/A N/A Access to integral heart rate system test function (for use by authorized
Test Maintenance Technician).
Measurements N/A N/A N/A Access to integral Measurements function (for use by authorized
Maintenance Technician).
Auto Status N/A N/A OFF Turns on/off the unsolicited status of the CSAFE feature.